Home Page
ꄲ
Frequency Converter Series
ꄲ
Frequency Converter Series
ꄲ
V3 Economical Frequency Converter
ꄲ
V3 Universal [7.5 kw-15kw]
V3 Universal [7.5 kw-15kw]
V3 inverter
| classification | Specific parameter items | Details |
|---|---|---|
| Input | Rated voltage and frequency | three-phase (4T series) 380V:50/60Hz; three-phase (2T series) 220V:50/60Hz |
| voltage | three-phase (4T series) 320V ~ 460V; three-phase (2T series) 190V ~ 250V | |
| Output | voltage | 4T series: 0~380V;2T series: 0~220V |
| frequency | V/F control, simple vector control: 0.0~999.9Hz; advanced vector control, torque control: 0.5~300.0Hz | |
| Overload Capacity | 110% long term; 150% 1 min; 180% 5 sec | |
| control mode | V/F control, simple vector control, advanced vector control, torque control | |
| Control Features | frequency setting resolution-analog input | 0.1% of maximum output frequency |
| frequency setting resolution-digital setting | 0.1Hz | |
| Frequency Accuracy-Analog Input | Within 0.2% of maximum output frequency | |
| Frequency Accuracy-Digital Inputs | Within 0.01% of the set output frequency | |
| V/F control | three ways: the first is the linear torque characteristic curve, the second is the square torque characteristic curve, the third is the user set V/F curve | |
| V/F Control-Torque Lift | Manual setting: rated output 0.0 - 30.0; automatic lifting: automatically determine the lifting torque according to the output current and motor parameters | |
| V/F Control-Automatic Current and Voltage Limiting | is accelerating, decelerating or running, it will automatically detect the stator current and voltage, and suppress it within the allowable range according to the algorithm to reduce the possibility of system fault tripping. | |
| No Speed Vector Control-Voltage Frequency Characteristics | Automatically adjust the output voltage-frequency ratio according to motor parameters and algorithms | |
| no-speed vector control-torque characteristics | 100% rated torque at 5.0Hz (V/F control); 150% rated torque at 1.0Hz (vector control); 100% rated torque at 5.0Hz (V/F control); 150% rated torque at 1.0Hz (vector control) | |
| No Speed Vector Control-Current and Voltage Repression | Full current closed-loop control to avoid current impact, with over-current and over-voltage suppression function | |
| No Speed Vector Control-Under Voltage Suppression in Operation | For low voltage or voltage fluctuation users, when the voltage is lower than the allowable range, the system maintains the maximum feasible operation time according to the unique allocation strategy. | |
| Multi-speed operation | 7-segment programmable multi-speed control with optional multiple operation modes | |
| Typical functions | PID control, RS485 communication | Built-in PID controller (preset frequency), standard configuration RS485 communication function, a variety of communication protocols optional, with linkage synchronous control input function |
| Frequency Setting-Analog Input | DC voltage 0 - 10V, DC current 0-20mA (upper and lower limits can be selected) | |
| frequency setting-digital input | operation panel settings, RS485 interface settings, UP/DOWN terminal control, can also be combined with analog input control | |
| frequency setting-relay output | 1 relay output (TA,TC), up to 17 meaning options | |
| Output Signal-Analog Output | 1-channel analog output, the output range is flexibly set between 0-20mA or 0 - 10V, which can realize the output of physical quantities such as set frequency and output frequency. | |
| Automatic voltage stabilizing operation | According to the needs of the optional dynamic voltage regulator, static voltage regulator, unregulated three ways to obtain the most stable operation effect | |
| acceleration and deceleration time setting | 0.15 - 999.0min continuously settable | |
| braking-energy consumption braking | Energy consumption braking starting voltage, return voltage and energy consumption braking rate are continuously adjustable | |
| brake-DC brake | shutdown DC braking: 0.00 ~[F00.5] upper limit frequency; Braking time: 0.0~30.0s; Braking current: 0.0~50.0 of rated current of motor | |
| Low noise operation | carrier frequency 2.0KHz ~ 20.0KHz continuously adjustable to minimize motor noise | |
| counter | Built-in counter one, easy to integrate the system | |
| operation function | upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency diff and decrement control, fault self-recovery operation, etc. | |
| Display | Operation Panel Display-Running Status | output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc. |
| operation panel display-alarm content | the latest fault when the output frequency, set frequency, output current, output voltage, DC voltage, module temperature and other operating parameters record | |
| environment | protection function | Over current, over voltage, under voltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc. |
| ambient temperature | -10 ℃ ~ +40 ℃ (the ambient temperature is 40 ℃ ~ 50 ℃, please use derating) | |
| ambient humidity | 5% ~ 95% RH, no water beads condensation | |
| surrounding environment | indoor (no direct sunlight, no corrosion, flammable gas, no oil mist, dust, etc.) | |
| elevation | derating for use over 1000 m, 10% derating for every 1000 m rise | |
| structure | protection level | IP20 |
| cooling method | air-cooled, with fan control | |
| Installation Method | Wall-mounted type, cabinet type |
inverter
Specific characteristics of advantage categories
Strong adaptability The input voltage covers 200-240V single-phase/three-phase, 380-480V three-phase, and adapts to wide voltage fluctuations. Support wall-mounted/cabinet installation, and adapt to -10 ℃ ~ 40 ℃ environment.
Accurate and efficient control 0-300Hz frequency adjustable, resolution 0.1Hz, speed regulation range 1:50; With V/F, vector and other control modes, 150 overload capacity lasts for 1 minute, meeting complex working c
Specific characteristics of advantage categories
Strong adaptability The input voltage covers 200-240V single-phase/three-phase, 380-480V three-phase, and adapts to wide voltage fluctuations. Support wall-mounted/cabinet installation, and adapt to -10 ℃ ~ 40 ℃ environment.
Accurate and efficient control 0-300Hz frequency adjustable, resolution 0.1Hz, speed regulation range 1:50; With V/F, vector and other control modes, 150 overload capacity lasts for 1 minute, meeting complex working c